Products
Piping type vortex shedding flowmeter
1.Brief introduction
It measures volume flow of gas, steam and liquid based on Karman theory.
2.Features
No movable parts, long term stability, simple structure, convenient for installation and maintenance;
Transducer output is impulse frequency;
High accuracy, stable performance, and multiple structures;
Flexible installation method;
3.Application
It is widely applied in large, middle and small size pipeline discharging field, industrial circulating, sewage treatment, oils, chemical reagents, compressed air, saturated steam, natural gas and various medium flow measurements.
4.Technical index
executive standard
(JB/T9249—1999)
caliber(mm)
15.20.25.32.40.50.65.80.100.
125.150.200.250.300
nominal pressure(MPa)
1.6MPa.
2.5MPa.4.OMPa
accuracy level
liquid: ±1%
gas or steam: ±1.5%.±1%
range ratio
1∶10; 1∶15; 1∶20
material of sensor
304 stainless steel.316(L) stainless steel等
application condition
medium temperature: -40°C~+250°C.-40°C~+350°C
environment temperature: -20°C~+60°C
relative humidity: 5%~90%
air pressure: 86Kpa~106Kpa
signal output function
pulse signal.4~20mA
communication output function
RS485 .HART
hazardous rating
ExiaIICT5 or ExdIIBT6
level of protection
IP65 or higher
Structural style and installation size
1.flange connection type
DN
L
H
installation flange
construction bolt
specifications of matched pipes
flange exterior diameter
flange thickness
hole spacing
bolt hole diameter
quantities
specifications
15
180
415
95
14
65
14
8
M12×60
φ18×1.5
20
180
420
105
16
75
14
8
M12×60
φ25×2.5
25
180
425
115
16
85
18
8
M16×60
φ32×3.5
32
180
435
140
18
100
18
8
M16×70
φ39×3.5
40
180
435
150
18
110
18
8
M16×70
φ48×4
50
180
440
165
20
125
18
8
M16×70
φ59×4.5
65
180
460
185
20
145
18
8
M16×70
φ74×4.5
80
200
490
200
20
160
18
16
M16×70
φ89×4.5
100
220
510
220
22
180
18
16
M16×80
φ109×4.5
125
240
535
250
22
210
18
16
M16×80
φ134×4.5
150
170
570
285
24
240
22
16
M20×80
φ159×4.5
200
300
625
340
26
295
22
24
M20×90
φ219×9
250
320
685
405
28
355
26
24
M24×100
φ273×11
300
350
710
460
32
410
26
24
M24×100
φ325×12
flange type
DN
L
Lo
H
D
specifications of matched pipes
15
80
116
400
68
φ18×1.5
20
80
116
400
68
φ25×2.5
25
80
116
400
68
φ32×3.53
32
80
116
400
68
φ39×3.5
40
80
116
404
80
φ49×4.5
50
80
116
412
88
φ59×4.5
65
80
116
428
105
φ74×4.5
80
80
116
446
120
φ89×4.5
100
80
118
472
148
φ109×4.5
125
85
124
492
174
φ134×4.5
150
90
135
515
196
φ159×4.5
200
105
150
570
250
φ219×9
250
120
166
620
300
φ273×11
300
135
185
670
350
φ325×12
It measures volume flow of gas, steam and liquid based on Karman theory.
2.Features
No movable parts, long term stability, simple structure, convenient for installation and maintenance;
Transducer output is impulse frequency;
High accuracy, stable performance, and multiple structures;
Flexible installation method;
3.Application
It is widely applied in large, middle and small size pipeline discharging field, industrial circulating, sewage treatment, oils, chemical reagents, compressed air, saturated steam, natural gas and various medium flow measurements.
4.Technical index
executive standard | (JB/T9249—1999) |
caliber(mm) | 15.20.25.32.40.50.65.80.100. 125.150.200.250.300 |
nominal pressure(MPa) | 1.6MPa. 2.5MPa.4.OMPa |
accuracy level | liquid: ±1% gas or steam: ±1.5%.±1% |
range ratio | 1∶10; 1∶15; 1∶20 |
material of sensor | 304 stainless steel.316(L) stainless steel等 |
application condition | medium temperature: -40°C~+250°C.-40°C~+350°C environment temperature: -20°C~+60°C relative humidity: 5%~90% air pressure: 86Kpa~106Kpa |
signal output function | pulse signal.4~20mA |
communication output function | RS485 .HART |
hazardous rating | ExiaIICT5 or ExdIIBT6 |
level of protection | IP65 or higher |
Structural style and installation size
1.flange connection type
DN | L | H | installation flange | construction bolt | specifications of matched pipes | ||||
flange exterior diameter | flange thickness | hole spacing | bolt hole diameter | quantities | specifications | ||||
15 | 180 | 415 | 95 | 14 | 65 | 14 | 8 | M12×60 | φ18×1.5 |
20 | 180 | 420 | 105 | 16 | 75 | 14 | 8 | M12×60 | φ25×2.5 |
25 | 180 | 425 | 115 | 16 | 85 | 18 | 8 | M16×60 | φ32×3.5 |
32 | 180 | 435 | 140 | 18 | 100 | 18 | 8 | M16×70 | φ39×3.5 |
40 | 180 | 435 | 150 | 18 | 110 | 18 | 8 | M16×70 | φ48×4 |
50 | 180 | 440 | 165 | 20 | 125 | 18 | 8 | M16×70 |
φ59×4.5 |
65 | 180 | 460 | 185 | 20 | 145 | 18 | 8 | M16×70 | φ74×4.5 |
80 | 200 | 490 | 200 | 20 | 160 | 18 | 16 | M16×70 | φ89×4.5 |
100 | 220 | 510 | 220 | 22 | 180 | 18 | 16 | M16×80 | φ109×4.5 |
125 | 240 | 535 | 250 | 22 | 210 | 18 | 16 | M16×80 | φ134×4.5 |
150 | 170 | 570 | 285 | 24 | 240 | 22 | 16 | M20×80 | φ159×4.5 |
200 | 300 | 625 | 340 | 26 | 295 | 22 | 24 | M20×90 | φ219×9 |
250 | 320 | 685 | 405 | 28 | 355 | 26 | 24 | M24×100 | φ273×11 |
300 | 350 | 710 | 460 | 32 | 410 | 26 | 24 | M24×100 | φ325×12 |
flange type
DN | L | Lo | H | D | specifications of matched pipes |
15 | 80 | 116 | 400 | 68 | φ18×1.5 |
20 | 80 | 116 | 400 | 68 | φ25×2.5 |
25 | 80 | 116 | 400 | 68 | φ32×3.53 |
32 | 80 | 116 | 400 | 68 | φ39×3.5 |
40 | 80 | 116 | 404 | 80 | φ49×4.5 |
50 | 80 | 116 | 412 | 88 | φ59×4.5 |
65 | 80 | 116 | 428 | 105 | φ74×4.5 |
80 | 80 | 116 | 446 | 120 | φ89×4.5 |
100 | 80 | 118 | 472 | 148 | φ109×4.5 |
125 | 85 | 124 | 492 | 174 | φ134×4.5 |
150 | 90 | 135 | 515 | 196 | φ159×4.5 |
200 | 105 | 150 | 570 | 250 | φ219×9 |
250 | 120 | 166 | 620 | 300 | φ273×11 |
300 | 135 | 185 | 670 | 350 |
φ325×12 |
【LAST ONE】 【NEXT ONE】 【BACK】 |